Robotic Small Bowel Gastrointestinal Stromal Tumor Resection Using Indocyanine Green Perfusion Assessment and Intracorporeal Anastomosis
Article information
Abstract
Small bowel gastrointestinal stromal tumors (GISTs) account for 20%–30% of GISTs and are associated with more aggressive behavior than gastric lesions. Standard treatment for localized disease is R0 surgical resection with negative margins. Minimally invasive approaches have demonstrated oncologic outcomes comparable to those of open surgery, but technical descriptions of robotic resection incorporating adjunctive fluorescence imaging and intracorporeal anastomosis remain limited. This retrospective case review describes minimally invasive robotic small bowel GIST resection using indocyanine green (ICG) fluorescence to guide intraoperative perfusion assessment. Data on clinical presentation, diagnostic evaluation, operative technique, and postoperative outcomes were reviewed and used to prepare this case report. A 67-year-old male presented with abdominal discomfort and weight loss. Clinical workup included cross-sectional imaging, which showed a 3.9-cm distal small bowel mass without lymphadenopathy. The patient underwent endoscopic evaluation, which localized a proximal jejunal subepithelial lesion and included tattoo placement. Minimally invasive robotic surgical resection was performed. After mesenteric division, ICG near-infrared fluorescence confirmed adequate perfusion of the planned transection margins. A side-to-side functional end-to-end enteroenterostomy was completed intracorporeally, and the specimen was extracted in a protective specimen bag. The patient recovered without complications and was discharged on postoperative day 1. Pathology revealed a 3.9-cm low-grade spindle-cell GIST with negative margins. Robotic minimally invasive resection of a symptomatic small bowel GIST with intracorporeal anastomosis was feasible and consistent with established oncologic principles. ICG fluorescence imaging provided real-time perfusion assessment. Early multidisciplinary collaboration and selective diagnostic evaluation may help streamline care. This case illustrates the integration of advanced robotic platforms and fluorescence-guided near-infrared imaging in the management of small bowel GIST while maintaining adherence to established oncologic principles.
Introduction
Gastrointestinal stromal tumors (GISTs) are the most common mesenchymal tumors of the gastrointestinal tract and are primarily treated with surgical resection [1,2]. Small bowel GISTs are associated with more aggressive behavior and higher malignant potential compared to gastric lesions [3-5]. Minimally invasive approaches offer oncologic outcomes comparable to open surgery with improved perioperative recovery, including shorter length of stay and faster return of bowel function [6-8].
Despite increasing adoption of minimally invasive techniques, descriptions of technical strategies for robotic small bowel GIST resection—particularly incorporating adjuncts such as indocyanine green (ICG) fluorescence imaging—remain limited. Optimization of intraoperative perfusion assessment and intracorporeal reconstruction may further enhance surgical precision and outcomes. We present a robotic-assisted small bowel GIST resection demonstrating intracorporeal anastomosis and the use of ICG fluorescence to guide intraoperative perfusion assessment.
The Kaiser Permanente Southern California Institutional Review Board approved the study (approval no. 14507).
Case Presentation
A 67-year-old male with a history of hypertension presented with gastrointestinal symptoms including abdominal discomfort, diarrhea, and unintentional weight loss. Cross-sectional imaging demonstrated a 3.9 cm hyper-enhancing small bowel mass without associated lymphadenopathy (Fig. 1). The lesion appeared intraluminal and raised concern for a neoplastic process.
Cross-sectional imaging demonstrating the small bowel mass. (A) Coronal computed tomography (CT) image demonstrating the same lesion (arrow) measuring approximately 3.9 cm. (B) Axial CT demonstrating a hyper-enhancing intraluminal lesion (arrow) within the distal small bowel.
Further evaluation with capsule endoscopy and double-balloon enteroscopy confirmed a subepithelial lesion in the jejunum. The lesion was marked with India ink tattoo to facilitate intraoperative localization. Given the size and imaging characteristics, surgical resection was recommended. The patient was evaluated by a multidisciplinary team and deemed an appropriate candidate for minimally invasive resection. A robotic-assisted approach was selected to facilitate precise dissection and intracorporeal reconstruction.
Operative technique
Under general endotracheal anesthesia, access was gained into the abdomen using left subcostal Veress needle insertion technique, and pneumoperitoneum established to 12 mmHg without event. A 5 mm port was placed under direct visualization in the left subcostal incision site. Bilateral transversus abdominis plane and rectus sheath blocks were performed with 0.25% bupivacaine. Four additional robotic ports were placed across the lower abdomen, and the 5 mm port was exchanged for an Air Seal port (ConMed Corporation), all under direct laparoscopic visualization. The patient was then placed in moderate Trendelenburg position. After docking the robotic patient cart, the overlying omentum was retracted cephalad and the small bowel mass was immediately identified, including the endoscopic tattoo localization (Fig. 2).
A small bowel resection with primary anastomosis was performed. The small bowel mesentery was divided using a vessel sealer. ICG fluorescence imaging with near-infrared technology was then utilized to confirm adequate perfusion at the planned bowel transection and anastomotic sites (Fig. 3). A 3 mL bolus of ICG (2.5 mg/mL), followed by a 10 mL saline flush, was administered intravenously. The interval from injection to fluorescence visualization was approximately 1 minute. Once adequate perfusion to the planned area of bowel anastomosis was confirmed, proximal and distal enterotomies were then created to facilitate simultaneous resection and anastomosis. A side-to-side enteroenterostomy was constructed using a 60-mm blue-load robotic stapler. Additional stapler firings were performed to close the enterotomy sites and complete the small bowel anastomosis.
Intraoperative Firefly near-infrared fluorescence imaging using the Intuitive Surgical da Vinci Surgical System confirming adequate perfusion at the planned transection and anastomotic sites.
The specimen was placed in a specimen bag. The robotic patient cart was undocked. The suprapubic port was enlarged and a small wound protector was placed to facilitate specimen extraction. Following specimen extraction, the abdomen was desufflated, and all remaining ports were removed. The extraction site fascia was closed with running looped 0-PDS (Ethicon) and the remaining skin incision and port sites skin incisions were closed with 4-0 Monocryl (Ethicon). The patient was extubated and transferred to recovery in stable condition. There were no intraoperative events and blood loss was less than 5 mL.
Postoperative course
The patient had an uncomplicated postoperative course, tolerated diet, and was discharged on postoperative day 1. Final pathology demonstrated a low-grade GIST with negative margins. Following multidisciplinary review, surveillance imaging was recommended without adjuvant therapy.
Discussion
This case demonstrates the feasibility of robotic small bowel GIST resection incorporating intracorporeal anastomosis and ICG fluorescence perfusion assessment. Surgical resection with negative margins remains the cornerstone of treatment for localized GIST, and minimally invasive approaches provide comparable oncologic outcomes with improved postoperative recovery [9,10]. The robotic platform offers enhanced visualization, articulation, and stability, facilitating precise mesenteric division and intracorporeal reconstruction while minimizing bowel manipulation and improving operative ergonomics.
Preoperative localization strategies, including capsule endoscopy and double-balloon enteroscopy with tattooing, may assist in identifying lesions that are intraluminal or difficult to visualize intraoperatively. In this case, tattooing facilitated rapid identification of the lesion and streamlined operative workflow. However, many small bowel GISTs are exophytic and readily identifiable during exploration, and extensive diagnostic evaluation may not be necessary when cross-sectional imaging clearly demonstrates a suspicious mass. Selective use of localization techniques may therefore reduce unnecessary procedures while maintaining operative efficiency.
ICG fluorescence imaging was used intraoperatively to confirm adequate perfusion at the planned transection margins and anastomotic segments. While routine use has not consistently demonstrated a reduction in anastomotic complications, fluorescence angiography remains a safe, rapid, and reproducible adjunct that may influence intraoperative decision-making when perfusion is uncertain. This may be particularly valuable in minimally invasive surgery, where tactile feedback is limited and visual cues are critical.
This approach highlights the integration of advanced robotic platforms and fluorescence-guided imaging in the surgical management of small bowel GIST, allowing surgeons to combine oncologic principles with contemporary minimally invasive techniques to optimize perioperative outcomes.
Notes
Disclosure
No potential conflict of interest relevant to this article was reported.
Author contributions
Conceptualization: NA, JNP, NK, ECM; Data curation: NA, JNP, NK, ECM; Formal analysis: NA, JNP, NK, ECM; Investigation: NA, JNP, NK, ECM; Methodology: NA, JNP, NK, ECM; Project administration: NA, JNP, NK, ECM; Resources: NA, JNP, NK, ECM; Supervision: JNP, NK, ECM; Validation: NA, JNP, NK, ECM; Visualization: NA, JNP, NK, ECM; Writing–original draft: NA; Writing–review & editing: NA, JNP, NK, ECM.